Stat-X Condensed Aerosol Fire Suppression

Stat-X Condensed Aerosol Fire Suppression

Suppression without cylinders, piping, or pressure.

Stat-X® is a condensed aerosol fire suppression system built into self-contained generators. It stops fire chemically, installs in a fraction of the space of gaseous systems, and has zero ozone depletion potential, zero global warming potential, and zero atmospheric lifetime.

What it is

A fixed system with no cylinders or piping.

Stat-X is a fixed fire suppression system made up of one or more aerosol generators mounted inside the space they protect. Each generator is a stainless steel unit containing a solid, potassium-based aerosol-forming compound. It is not pressurized until activation, so there are no agent cylinders, manifolds, or piping. Generators are available in sizes for enclosures ranging from small cabinets to large machinery rooms. A system uses as many generators as the protected volume requires.

Stat-X systems are designed, installed, and maintained under NFPA 2010, the standard for fixed aerosol fire-extinguishing systems, and are listed to UL 2775. See What is condensed aerosol fire suppression?

How it works

It stops the chain reaction, not the oxygen.

On activation, the compound converts to an ultra-fine aerosol of potassium-based particles suspended in nitrogen gas. The aerosol fills the enclosure and interrupts the chemical chain reaction of combustion. It does not work by removing oxygen or by cooling. The aerosol is non-conductive, and Stat-X is listed for Class A (surface), Class B, and Class C fires, including energized electrical equipment.

The aerosol stays suspended for an extended period after discharge, protecting the space against re-ignition while the cause of the fire is addressed. Activation can be electrical from a detection and control panel, thermal by a fixed-temperature element, or manual. See How Stat-X works.

Where it is used

Enclosed special hazards, on land and at sea.

Stat-X protects enclosed special hazards where water is unsuitable and gaseous systems are too large, too heavy, or too costly to maintain:

  • Battery energy storage systems, solar inverters, and wind turbine nacelles
  • Switchgear, transformers, control cabinets, and power generation equipment
  • Telecommunications equipment rooms, data center ancillary equipment, and utility substations
  • Machinery spaces on commercial, government, and naval vessels
  • Engine compartments on buses, rail vehicles, and mining equipment

Stat-X generators are installed in more than 90 countries. Application details are on the Stat-X industries and applications pages.

Approvals & Listings

Tested and listed by independent bodies.

  • UL and ULC listed to UL 2775, with a listed 15-year service life
  • UL-EU certified to EN 15276-1 for the European market
  • U.S. EPA SNAP listed for total flooding in normally occupied and unoccupied spaces
  • U.S. Coast Guard Certificate of Approval for pre-engineered thermal systems in shipboard enclosed spaces up to 73 m³
  • Type approved by Bureau Veritas following evaluation in accordance with IMO MSC.1/Circ.1270, with EU Marine Equipment Directive and UK Merchant Shipping (Marine Equipment) Regulations certification

Fireaway manufactures Stat-X under ISO 9001:2015 and ISO 14001:2015 certified management systems. Certificate details are on the listings and approvals page.

Environment

Outside the HFC and PFAS phasedowns.

Stat-X has zero ozone depletion potential, zero global warming potential, and zero atmospheric lifetime. It contains no hydrofluorocarbons and no per- or polyfluoroalkyl substances. That places it outside the U.S. HFC phasedown under the AIM Act and the regulatory actions on PFAS chemistry, and it is unaffected by 3M’s exit from Novec 1230 production. Owners of HFC systems can expect changes in agent availability and cost and, from 2030, servicing with recycled agent. Stat-X owners are not affected. See What does the AIM Act mean for fire suppression?

Why owners choose it

Less space, less weight, less maintenance.

  • Space and weight. No cylinder room, no piping runs. A Stat-X system for a 1,000-cubic-meter machinery space weighs a fraction of the equivalent CO2 system.
  • Maintenance. No pressure vessels requiring hydrostatic testing, no agent to weigh or refill. Periodic visual inspection in accordance with NFPA 2010 and the manufacturer’s instructions, and replacement at the end of the 15-year service life.
  • Installation. Generators mount directly in the enclosure and wire to a listed releasing panel, which simplifies retrofit compared with piped gaseous systems.

Next steps

Learn more.

Contact

Speak with a fire protection expert.